Customization: | Available |
---|---|
Certification: | CE |
Transport Package: | Carton |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Protective structure | IP67 | |
---|---|---|
Durability*1 | Mechanical | Over 15 million times*2 |
Electrical | Over 750,000 times*3 | |
Allowable Operating Speed | 1mm to 1m/s (for WLCA2) | |
Permissible operating frequency | Mechanical | 120 times/min |
Electrical | 30 times/min | |
Rated Frequency | 50/60Hz | |
Insulation resistance | 100MΩ or more (at DC500V mega) | |
Contact Resistance | 25mΩ or less (initial value, built-in switch only)*6 | |
Withstand voltage | Between same-polarity terminals | AC1,000V 50/60Hz 1min |
Between each terminal and earth | AC2,200V 50/60Hz 1min/Uimp 2.5kV | |
Between each terminal and non-current-carrying metal parts | AC2,200V (1,500V) 50/60Hz 1min/Uimp 2.5kV | |
Rated insulation voltage (Ui) | 250V (EN60947-5-1) | |
Pollution level (usage environment) | 3 (EN60947-5-1) | |
Short Circuit Protection Device | 10A fuse type gG or gI (IEC269) | |
Conditional Short Circuit Current | 100A (EN60947-5-1) | |
Rated sealed thermal current (I the) | 10A, 0.5A (EN60947-5-1) | |
Electric shock protection class | Class I | |
vibration | malfunction | 10 to 55Hz, double amplitude 1.5mm *4 |
impact | Durability | Up to 1,000m/s2 |
malfunction | Maximum 300m/s2* 4 | |
Ambient temperature | -10 to +80ºC (but do not freeze) *5 | |
Ambient humidity | 35~95% RH | |
mass | Approx. 275g (for WLCA2) |
Note 1. The above values are initial values of Limit Switch.
Note 2. The values in parentheses for the withstand voltage are for the microload type.
*1. The durability values are for an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*2. For overtravel general type and flexible rod type, it is 10 million times or more. For weather-
resistant type, it is 500,000 times or more.
*3. For microload type, it is 1 million times or more. For weather-
resistant type, it is 500,000 times or more.
*4. Flexible rod type is excluded. For microload type, it is up to 200 m/s2.*
5. For cold-resistant type, it is -40 to +40°C (but do not freeze).
For heat-resistant type, it is +5 to +120°C.
*6. For microload type, it is 50 mΩ or less (initial value, built-in switch only)
(Operating Characteristics) | Model | (Model) WLC A2 (Model) WL01 CA2 |
---|---|---|
Operating Force, OF | (Max) | 13.34N |
Return Force, RF | (Min) | 2.23N |
Pre-Travel, PT | 15 ± 5° | |
Over-Travel, OT | (Min) | 30° |
Differential Travel, MD | (Max) | 12° |
Shenzhen Aimiqu Technology Co., Ltd. |
Shenzhen Aimiqu Technology Co., Ltd. was established in 2016 and is located in Bao'an District, Shenzhen. The company has professional technical personnel, focusing on the development and practice of automation, digitalization, networking and intelligence in the industrial field. Shenzhen Aimiqu is a factory specializing in production & sales & research in electric cabinet. And Shenzhen Aimiqu is a specializing in sales original PLC&pneumatic products & Industrial Control Instrumentation including Siemens,Fairchild and ST etc and related accessories . In PLC&Pump Valve & Pneumatic industry&Industrial Control Instrumentation has a strong popularity and good reputation,and provide professional customized services(Our main business is according to customer dr... |
1.Who we are We focus on the PLC, instrument and transmitters industry, mainly selling world-famous PLC,instrument and transmitters brands 2.Our advantage We have been in the industry for many years, and we have strong supply chain relationships and large inventories, with great price advantages. I will try my best to give you the best price,prove that we are sincere. 3.Our Service Purpose We want to build a long-term stable relationship, not a one-off business, to achieve a win-win goal 4.Lead-Time Depending on thr model and quantity you need.So please tell us what you need now 5.Can't find the model you need? We have only shown some models,If the model you need is not found here,please contact us |