General technical data | ||
product brand name | SIRIUS | |
product designation | Soft starter | |
product feature | ||
integrated bypass contact system | Yes | |
thyristors | Yes | |
product function | ||
intrinsic device protection | Yes | |
motor overload protection | Yes | |
evaluation of thermistor motor protection | No | |
external reset | Yes | |
adjustable current limitation | Yes | |
inside-delta circuit | No | |
product component motor brake output | No | |
insulation voltage rated value | V | 600 |
degree of pollution | 3, acc. to IEC 60947-4-2 | |
blocking voltage of the thyristor maximum | V | 1 600 |
reference code according to EN 61346-2 | Q | |
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G | |
Power Electronics | ||
operational current | ||
at 40 °C rated value | A | 45 |
at 50 °C rated value | A | 42 |
at 60 °C rated value | A | 39 |
yielded mechanical performance for 3-phase motors | ||
at 230 V | ||
- at standard circuit at 40 °C rated value | kW | 11 |
at 400 V | ||
- at standard circuit at 40 °C rated value | kW | 22 |
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value | hp | 10 |
operating frequency rated value | Hz | 50 ... 60 |
relative negative tolerance of the operating frequency | % | -10 |
relative positive tolerance of the operating frequency | % | 10 |
operating voltage at standard circuit rated value | V | 200 ... 480 |
relative negative tolerance of the operating voltage at standard circuit | % | -15 |
relative positive tolerance of the operating voltage at standard circuit | % | 10 |
minimum load [%] | % | 20 |
adjustable motor current for motor overload protection minimum rated value | A | 23 |
continuous operating current [% of Ie] at 40 °C | % | 115 |
power loss [W] at operational current at 40 °C during operation typical | W | 6 |
Control circuit/ Control | ||
type of voltage of the control supply voltage | AC/DC | |
control supply voltage frequency 1 rated value | Hz | 50 |
control supply voltage frequency 2 rated value | Hz | 60 |
relative negative tolerance of the control supply voltage frequency | % | -10 |
relative positive tolerance of the control supply voltage frequency | % | 10 |
control supply voltage 1 at AC | ||
at 50 Hz rated value | V | 24 |
at 60 Hz rated value | V | 24 |
relative negative tolerance of the control supply voltage at AC at 50 Hz | % | -15 |
relative positive tolerance of the control supply voltage at AC at 50 Hz | % | 10 |
relative negative tolerance of the control supply voltage at AC at 60 Hz | % | -15 |
relative positive tolerance of the control supply voltage at AC at 60 Hz | % | 10 |
control supply voltage 1 at DC rated value | V | 24 |
relative negative tolerance of the control supply voltage at DC | % | -20 |
relative positive tolerance of the control supply voltage at DC | % | 20 |
display version for fault signal | red | |
Mechanical data | ||
size of engine control device | S2 | |
width | mm | 55 |
height | mm | 160 |
depth | mm | 170 |
fastening method | screw and snap-on mounting | |
mounting position | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t |
|
required spacing with side-by-side mounting | ||
upwards | mm | 60 |
at the side | mm | 30 |
downwards | mm | 40 |
wire length maximum | m | 300 |
number of poles for main current circuit | 3 | |
Connections/ Terminals | ||
type of electrical connection | ||
for main current circuit | screw-type terminals | |
for auxiliary and control circuit | screw-type terminals | |
number of NC contacts for auxiliary contacts | 0 | |
number of NO contacts for auxiliary contacts | 2 | |
number of CO contacts for auxiliary contacts | 1 | |
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point | ||
solid | 2x (1.5 ... 16 mm²) | |
finely stranded with core end processing | 0.75 ... 25 mm² | |
stranded | 0.75 ... 35 mm² | |
type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point | ||
solid | 2x (1.5 ... 16 mm²) | |
finely stranded with core end processing | 1.5 ... 25 mm² | |
stranded | 1.5 ... 35 mm² | |
type of connectable conductor cross-sections for main contacts for box terminal using both clamping points |
solid | 2x (1.5 ... 16 mm²) | |
finely stranded with core end processing | 2x (1.5 ... 16 mm²) | |
stranded | 2x (1.5 ... 25 mm²) | |
type of connectable conductor cross-sections for AWG cables for main contacts for box terminal | ||
using the back clamping point | 16 ... 2 | |
using the front clamping point | 18 ... 2 | |
using both clamping points | 2x (16 ... 2) | |
type of connectable conductor cross-sections for auxiliary contacts | ||
solid | 2x (0.5 ... 2.5 mm²) | |
finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) | |
type of connectable conductor cross-sections for AWG cables | ||
for auxiliary contacts | 2x (20 ... 14) | |
for auxiliary contacts finely stranded with core end processing | 2x (20 ... 16) | |
Ambient conditions | ||
installation altitude at height above sea level | m | 5 000 |
environmental category | ||
during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) | |
during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 | |
during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 | |
ambient temperature | ||
during operation | °C | -25 ... +60 |
during storage | °C | -40 ... +80 |
derating temperature | °C | 40 |
protection class IP on the front according to IEC 60529 | IP20 | |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |
UL/CSA ratings | ||
yielded mechanical performance [hp] for 3-phase AC motor | ||
at 220/230 V | ||
- at standard circuit at 50 °C rated value | hp | 15 |
at 460/480 V | ||
- at standard circuit at 50 °C rated value | hp | 30 |
contact rating of auxiliary contacts according to UL | B300 / R300 |