Customization: | Available |
---|---|
IP Rating: | IP67 |
Certification: | CCC |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | LK-G5001V*1*2 | |
Separate type | LK-G5001/LK-HD500 | |
Type | Main controller | |
Sensor head compatibility | Compatible | |
No. of connectable sensor heads | 2 | |
Display | Minimum display unit | LK-HD500: 0.001 µm |
Display range | LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable) | |
Display cycle | LK-HD500: Approx. 10 times/sec. | |
Display interface | Display port | Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected |
LED indicator | LASER ON | |
Terminal block | Analog output voltage | ±10 V output, Output impedance: 100 |
Analog current output | 4 to 20 mA, Maximum load resistance: 350 | |
No. of analog outputs | 2 | |
TIMING 1 input | Non-voltage input*3 | |
RESET 1 input | ||
Auto-zero 1 input | ||
Laser control input | Non-voltage input*4 | |
Laser remote input | Non-voltage input | |
Alarm output | NPN open-collector output | |
General comparator output | ||
Expansion connector | TIMING input | Non-voltage input |
RESET input | ||
Auto-zero input | ||
Program switching input | ||
Binary selection input | ||
Alarm output | NPN open-collector output | |
Comparator output | ||
Binary output | ||
RS-232C interface | Baud rate: 9,600 to 115,200 bps Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd |
|
USB interface | USB 2.0 Hi-Speed compliant*5 | |
Ethernet interface | 100Base-TX/10Base-T*6 | |
EtherNet/IP®interface | Cyclic communication (implicit messaging) Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*7 |
|
PLC-Link | The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series EtherNet/IP®, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link |
|
Head expansion unit connector | Up to 10 head expansion units can be connected to one main controller | |
Expansion unit connector | Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected | |
Power supply | Power supply voltage | 24 VDC ±10 % |
Maximum current consumption | 0.6 A or less with 1 head/3.5 A or less with 12 heads | |
Environmental resistance | Ambient temperature | When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F. When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F. |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | Approx. 600 g |