Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | ISO, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SIMATIC DP, CPU 1510SP-1 PN for ET 200SP, Central processing unit with Work memory 100 KB for program and 750 KB for data, 1st interface: PROFINET IRT with 3-port swit72 ns bit performance, SIMATIC Memory Card required, BusAdapter required for Port 1 and 2 | |
General information | |
Product type designation | CPU 1510SP-1 PN FS05 V2.9 |
HW functional status | |
Firmware version | |
Product function | |
|
Yes; I&M0 to I&M3 Yes; Multi-hot swapping Yes; Only with PROFINET; with minimum OB 6x cycle of 625 µs |
Engineering with | |
|
V17 (FW V2.9) / V13 SP1 Update 4 (FW V1.8) or higher |
Configuration control | |
via dataset | Yes |
Control elements | |
Mode selector switch | 1 |
Supply voltage | |
Rated value (DC) | 24 V 19.2 V 28.8 V Yes |
permissible range, lower limit (DC) | |
permissible range, upper limit (DC) | |
Reverse polarity protection | |
Mains buffering | |
|
5 ms |
Input current | |
Current consumption (rated value) | 0.6 A 0.9 A 4.7 A; Rated value 0.14 A²·s |
Current consumption, max. | |
Inrush current, max. | |
I²t | |
Power | |
Infeed power to the backplane bus | 8.75 W |
Power loss | |
Power loss, typ. | 5.6 W |
Memory | |
Number of slots for SIMATIC memory card | 1 Yes |
SIMATIC memory card required | |
Work memory | |
|
100 kbyte 750 kbyte |
Load memory | |
|
32 Gbyte |
Backup | |
|
Yes |
CPU processing times | |
for bit operations, typ. | 72 ns 86 ns 115 ns 461 ns |
for word operations, typ. | |
for fixed point arithmetic, typ. | |
for floating point arithmetic, typ. | |
CPU-blocks | |
Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
DB | |
|
1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 750 kbyte; For DBs with absolute addressing, the max. size is 64 KB |
FB | |
|
0 ... 65 535 100 kbyte |
FC | |
|
0 ... 65 535 100 kbyte |
OB | |
|
100 kbyte 100 20 20 20; With minimum OB 3x cycle of 500 µs 50 3 1 2 100 4 2 1 |
Nesting depth | |
|
24 |
Counters, timers and their retentivity | |
S7 counter | |
|
2 048 |
Retentivity | |
- adjustable | Yes |
IEC counter | |
|
Any (only limited by the main memory) |
Retentivity | |
- adjustable | Yes |
S7 times | |
|
2 048 |
Retentivity | |
- adjustable | Yes |
IEC timer | |
|
Any (only limited by the main memory) |
Retentivity | |
- adjustable | Yes |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB |
Flag | |
|
16 kbyte 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks |
|
Yes No |
Local data | |
|
64 kbyte; max. 16 KB per block |
Address area | |
Number of IO modules | 1 024; max. number of modules / submodules |
I/O address area | |
|
32 kbyte; All inputs are in the process image 32 kbyte; All outputs are in the process image |
per integrated IO subsystem | |
|
8 kbyte 8 kbyte |
per CM/CP | |
|
8 kbyte 8 kbyte |
Subprocess images | |
|
32 |
Address space per module | |
|
288 byte; For input and output data respectively |
Address space per station | |
|
2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules |
Hardware configuration | |
Number of distributed IO systems | 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
Number of DP masters | |
|
1 |
Number of IO Controllers | |
|
1 |
|
0 |
Rack | |
|
80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 |
ET 200AL modules | |
|
64 |
|
16 |
|
1 |
PtP CM | |
|
the number of connectable PtP CMs is only limited by the number of available slots |
Time of day | |
Clock | |
|
Hardware clock 6 wk; At 40 °C ambient temperature, typically 10 s; Typ.: 2 s |
Operating hours counter | |
|
16 |
Clock synchronization | |
|
Yes |
|
Yes; Via CM DP module |
|
Yes; Via CM DP module |
|
Yes |
|
Yes |
|
Yes |
Interfaces | |
Number of PROFINET interfaces | 1 1; Via CM DP module No |
Number of PROFIBUS interfaces | |
Optical interface |