• 6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
  • 6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
  • 6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
  • 6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC

6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC

Task: Digital Output
Structure: Closed-Loop
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Digital Output
Certification: CE
Samples:
US$ 850/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
6ES7136-6RA00-0BF0
Condition
New
Customized
Non-Customized
Product Type Designation
F-Rq 24 ... 48VDC/24 ... 230VAC/5A St
Width
20 mm
Height
73 mm
Depth
58 mm
Transport Package
Carton
Specification
Weight, approx. 56g
Origin
German
HS Code
8538900000
Production Capacity
99999pieces/Year

Product Description

6ES7136-6RA00-0BF0 ET200SP Digital F-output module relay PLC
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC

Digital F-output module relay
Overview

The digital F electronic module relay 1 F-RQ DC 24VDC/24.230VAC/5 A has the following characteristics:

  • 1 relay output (2 NO contacts)
  • Total output current 5 A
  • Rated load voltage 24 V DC and 24 ... 230 V AC
  • The control circuit of the two safety relays must be routed from the outside to the respective terminals

The attainable safety integrity level is SIL 3 (IEC 61508) when the control of the F-RQ module is implemented via a fail-safe output (e.g. ET 200SP 4F-DQ 24 V DC/2 A PROFIsafe).

 
 

Application

The 1 F-RQ module is very versatile and can be used in multiple ways, e.g.

  • for switching of external voltages,
  • when floating signals are needed,
  • for controller releases,
  • when higher switching capacities (> 2 A) or other voltage levels are needed.
 

Design

Control must be carried out from the outside via a fail-safe electronic module to the respective IN P and IN M terminals. The ET 200SP 4 F-DQ (6ES7136-6DB00-0CA0) can be used for this, for example.

One channel of the 4 F-DQ module can be used to control a further 1 F-RQ module. The output signal can be looped through for this purpose: OUT P and OUT M of the first 1F-RQ module are wired to IN P and IN M of the second 1F-RQ module.

Data sheet                                                                                                          6ES7136-6RA00-0BF0
SIMATIC DP, Electronics module f. ET200SP, F-RQ 1x 24 V DC/24..230VAC/5A ST, 20 mm overall width, 1 relay output (2 NO) Summation output current 5 A, load voltage 24 V DC and 24.. 230 V AC, Can be used up to PL E (ISO 13849-1: 2008)/ SIL 3 (IEC 61508: 2010) if
control takes place by (e.g. 6ES7136-6DB00-0CA0) F-DQ
General information
Product type designation F-RQ 24 ... 48VDC/24 ... 230VAC/5A ST
BU type F0 CC42
usable BaseUnits
Color code for module-specific color identification plate
Product function
  • I&M data
Yes; I&M0 to I&M3
Engineering with
  • STEP 7 TIA Portal configurable/integrated from version
  • STEP 7 configurable/integrated from version
  • PROFINET from GSD version/GSD revision
V13

V5.5 SP4 and higher V2.31
Supply voltage
Rated value (DC) 24 V; Coil voltage
20.4 V
28.8 V No
permissible range, lower limit (DC)
permissible range, upper limit (DC)
power supply according to NEC Class 2 required
Power
Power available from the backplane bus 100 mW
Power loss
Power loss, typ. 1 W
Address area
Address space per module
  • Inputs
1 byte
Hardware configuration
Automatic encoding
  • Mechanical coding element
  • Type of mechanical coding element
Yes
Yes type C
Digital outputs
Type of digital output Relays 1
No
Yes
Number of digital outputs
Limitation of inductive shutdown voltage to
Controlling a digital input
Switching capacity of the outputs
  • with resistive load, max.
  • on lamp load, max.
5 A
25 W
Switching frequency
  • with resistive load, max.
  • with inductive load, max.
  • with inductive load (acc. to IEC 60947-5-1, DC13),
2 Hz
0.1 Hz; See data in manual
0.1 Hz
 
max.
  • with inductive load (acc. to IEC 60947-5-1, AC15), max.

2 Hz
Total current of the outputs (per module)
horizontal installation
  • up to 40 °C, max.
  • up to 50 °C, max.
  • up to 60 °C, max.
5 A; note derating data in the manual
4 A; note derating data in the manual 3 A; note derating data in the manual
vertical installation
- up to 50 °C, max. 3 A; note derating data in the manual
Relay outputs
  • Number of relay outputs
  • Rated supply voltage of relay coil L+ (DC)
  • Current consumption of relays (coil current of all relays), max.
  • external protection for relay outputs
  • Relay approved acc. to UL 508
1; 2 NO contacts
24 V
70 mA

yes; 6 A, see data in manual Yes; Pilot Duty B300, R300
Switching capacity of contacts
  • with inductive load, max.
  • with resistive load, max.
  • Thermal continuous current, max.
  • Switching current, min.
  • Switching current after exceeding 300 mA, min.
  • Switching current after exceeding 300 mA, max.
  • Rated switching voltage (DC)
  • Rated switching voltage (AC)
see additional description in the manual see additional description in the manual 5 A
1 mA
10 mA
5 A

24 V
230 V
Cable length
  • shielded, max.
  • unshielded, max.
  • Control cable (input), max.
500 m; for load contacts 300 m; for load contacts
10 m
Interrupts/diagnostics/status information
Diagnostics function Yes
Diagnostics indication LED
  • RUN LED
  • Channel status display
Yes; green/red DIAG LED
Yes; green LED
Potential separation
Potential separation channels
  • between the channels
  • between the channels and backplane bus
  • between the channels and the power supply of the electronics
Yes; for SELV / PELV only Yes
Yes
Permissible potential difference
between channels and backplane bus/supply voltage 250 V AC (reinforced insulation)
Isolation
Isolation tested with 2 545 V DC/2 s (routine test)
III
Overvoltage category
tested with
  • between channels and backplane bus/supply voltage
  • between backplane bus and supply voltage
DC 2 545 V 2 s (routine test), impulse voltage test DC 7 200 V / 5 positive and 5 negative pulses (type test)
707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functions Yes
Highest safety class achievable in safety mode
  • Performance level according to ISO 13849-1
  • Category according to ISO 13849-1
  • SIL acc. to IEC 61508
PLe 4
SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
  • Low demand mode: PFDavg in accordance with SIL2
  • Low demand mode: PFDavg in accordance
< 1.00E-04, function test 1x per year

< 1.00E-05, function test 1x per month
 
with SIL3
  • High demand/continuous mode: PFH in accordance with SIL2
  • High demand/continuous mode: PFH in accordance with SIL3

< 1.00E-08 1/h, function test 1x per year

< 6.00E-09 1/h, function test 1x per month
Ambient conditions
Ambient temperature during operation
  • horizontal installation, min.
  • horizontal installation, max.
  • vertical installation, min.
  • vertical installation, max.
0 °C
60 °C
0 °C
50 °C
Dimensions
Width 20 mm
73 mm
58 mm
Height
Depth
Weights
Weight, approx. 56 g



 
Shenzhen Aimiqu Technology Co., Ltd.

Shenzhen Aimiqu Technology Co., Ltd. was established in 2016 and is located in Bao'an District, Shenzhen. The company has professional technical personnel, focusing on the development and practice of automation, digitalization, networking and intelligence in the industrial field. Provide products, solutions and services for the majority of industrial enterprises and governments with automation systems, digital factories, industrial Internet and industrial big data intelligent integration, and strive to become a domestic intelligent manufacturing overall solution provider.


Shenzhen Aimiqu is a factory specializing in production & sales & research in electric cabinet.

And Shenzhen Aimiqu is a specializing in sales original PLC&pneumatic products & Industrial Control Instrumentation including Siemens,Fairchild and ST etc and related accessories .

In PLC&Pump Valve & Pneumatic industry&Industrial Control Instrumentation has a strong popularity and good reputation,and provide professional customized services(Our main business is according to customer dr...
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC

6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC

6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
Hot selling brand
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
Packing and shipping
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
                                                                                                                                                                                                              


FAQ
                                                                                                                                                                                                              
1.Who we are
  We focus on the PLC, instrument and transmitters industry, mainly selling world-famous PLC,instrument and transmitters brands

2.Our advantage
  We have been in the industry for many years, and we have strong supply chain relationships and large inventories, with great price advantages. 
  I will try my best to give you the best price,prove that we are sincere. 

3.Our Service Purpose
   We want to build a long-term stable relationship, not a one-off business, to achieve a win-win goal

4.Lead-Time
   Depending on thr model and quantity you need.So please tell us what you need now 

5.Can't find the model you need?
   We have only shown some models,If the model you need is not found here,please contact us
 
 

6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC
6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC6es7136-6ra00-0bf0 Et200sp Digital Relay Output Module PLC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now