Customization: | Available |
---|---|
After-sales Service: | One Year Warranty |
Principle: | Ultrasonic |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Field of applicationThe range of applications extends from monitoring levels in sewage treatment plants and process water tanks to applications for loading, storage and buffer tanks. FMU30 ultrasonic sensor offers proven software algorithms and all warning and alarm messages are shown on the four-line plain text display and guarantee fast remedy of problems. The envelope curve can also be shown on the display. As the analysis results are displayed directly on-site, this ensures quick and accurate error diagnostics. Two-wire instrument for continuous non-contact level and flow measurement.
Benefits
|
Measuring principle | Ultrasonic |
Characteristic / Application | Compact ultrasonic transmitter |
Supply / Communication | 2-wire |
Accuracy | +/- 3 mm or +/- 0,2 % of set measuring range |
Ambient temperature | -20 °C ... 60 °C (-4 °F ... 140 °F) |
Process temperature | -20 °C ... 60 °C (- 4°F ... 140 °F) |
Process pressure / max. overpressure limit | 0.7 bar ... 3 bar abs (10 psi ... 44 psi) |
Main wetted parts | PP/EPDM |
Process connection | G / NPT 1 1/2" G / NPT 2" |
Blocking distance | 1 1/2": 0.25 m (0.8 ft) 2":0.35 m (1.15 ft) |
Application | Application |
Max. measurement distance | Max. measurement distance |
Communication | 4...20 mA |
Certificates / Approvals | ATEX, CSA C/US, IEC Ex, NEPSI |
Options | Accessory Enclosed:UNI flange 2" ... 4" |
Application limits | Application limits |