Jumo Dtrans P02 Delta Pressure Transmitter

Product Details
Customization: Available
Customized: Non-Customized
Transport Package: Carton
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
101~500 square meters
  • Jumo Dtrans P02 Delta Pressure Transmitter
  • Jumo Dtrans P02 Delta Pressure Transmitter
  • Jumo Dtrans P02 Delta Pressure Transmitter
  • Jumo Dtrans P02 Delta Pressure Transmitter
  • Jumo Dtrans P02 Delta Pressure Transmitter
  • Jumo Dtrans P02 Delta Pressure Transmitter
Find Similar Products

Basic Info.

Model NO.
JUMO dTRANS p02 DELTA
Specification
JUMO dTRANS p02 DELTA
Trademark
AIMIQU
Origin
Germany
HS Code
8481100090
Production Capacity
9999999pieces/Year

Product Description

JUMO dTRANS p02 DELTA Pressure transmitter 
 
The product measures the differential pressure of non-aggressive and aggressive gases, steam, and liquids. The output signal is a load-independent direct current which is linearly proportional to the input pressure. For special applications, an extensive range of diaphragm seals is available.
General application
The JUMO dTRANS p02 DELTA pressure transmitter measures the differential pressure in both
corrosive and non-corrosive gases, vapors and liquids. The pressure transmitter makes use of
the piezo-resistive effect to make the measurement. The output signal is a DC current which is
linearly proportional to the input pressure. With flow-through measurements, it is possible to set
up the output signal to be proportional to the square-root of the input pressure.
In the version "with Ex protection Ex II 1/2 G Ex ia IIC T6 Ga/Gb", the transmitter can be moun
ted within the hazarduos area Zone 1, for connection to Zone 0.
A wide spectrum of pressure separators is available for special applications such as level mea
surements, or for corrosive media.
Display options:
• Pressure with choice of 13 different units
• Measurement in % or scaled with freely selectable dimensional unit
• Output current in mA
• Sensor temperature in °C or °F
• Measurement error, out-of-range measurement
• Minimum and maximum pressures (peak-reading pointer)
• Pressure and sensor temperature can be shown simultaneously (2 lines)
Setting options via keys:
• Start and end of measurement with pressure input
• Start and end of measurement without pressure input (blind setting)
• Damping or time constant
• Current generator function
• Output signal on error
• Key inhibit
• Reset min. and max. measured value (peak-reading pointer)
• Square-root characteristic (adjustable starting point), or linear
• Density correction for different measurement media
• Display of temperature of medium in °C or °F
The JUMO dTRANS p02 DELTA pressure transmitter can also be used with a HART® commu
nicator or a PC in conjunction with a HART® modem and the JUMO setup program running un
der Windows®.



Jumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure TransmitterJumo Dtrans P02 Delta Pressure Transmitter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier