General technical data | ||
product brand name | SIRIUS | |
product designation | Soft starter | |
product feature | ||
integrated bypass contact system | Yes | |
thyristors | Yes | |
product function | ||
intrinsic device protection | Yes | |
motor overload protection | Yes | |
evaluation of thermistor motor protection | No | |
external reset | Yes | |
adjustable current limitation | Yes | |
inside-delta circuit | No | |
product component motor brake output | No | |
insulation voltage rated value | V | 600 |
degree of pollution | 3, acc. to IEC 60947-4-2 | |
blocking voltage of the thyristor maximum | V | 1 600 |
reference code according to EN 61346-2 | Q | |
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G | |
Power Electronics | ||
operational current | ||
at 40 °C rated value | A | 25 |
at 50 °C rated value | A | 23 |
at 60 °C rated value | A | 21 |
yielded mechanical performance for 3-phase motors | ||
at 230 V | ||
- at standard circuit at 40 °C rated value | kW | 5.5 |
at 400 V | ||
- at standard circuit at 40 °C rated value | kW | 11 |
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value | hp | 5 |
operating frequency rated value | Hz | 50 ... 60 |
relative negative tolerance of the operating frequency | % | -10 |
relative positive tolerance of the operating frequency | % | 10 |
operating voltage at standard circuit rated value | V | 200 ... 480 |
relative negative tolerance of the operating voltage at standard circuit | % | -15 |
relative positive tolerance of the operating voltage at standard circuit | % | 10 |
minimum load [%] | % | 20 |
adjustable motor current for motor overload protection minimum rated value | A | 10 | |
continuous operating current [% of Ie] at 40 °C | % | 115 | |
power loss [W] at operational current at 40 °C during operation typical | W | 8 | |
Control circuit/ Control | |||
type of voltage of the control supply voltage | AC/DC | ||
control supply voltage frequency 1 rated value | Hz | 50 | |
control supply voltage frequency 2 rated value | Hz | 60 | |
relative negative tolerance of the control supply voltage frequency | % | -10 | |
relative positive tolerance of the control supply voltage frequency | % | 10 | |
control supply voltage 1 at AC | |||
at 50 Hz rated value | V | 24 | |
at 60 Hz rated value | V | 24 | |
relative negative tolerance of the control supply voltage at AC at 50 Hz | % | -15 | |
relative positive tolerance of the control supply voltage at AC at 50 Hz | % | 10 | |
relative negative tolerance of the control supply voltage at AC at 60 Hz | % | -15 | |
relative positive tolerance of the control supply voltage at AC at 60 Hz | % | 10 | |
control supply voltage 1 at DC rated value | V | 24 | |
relative negative tolerance of the control supply voltage at DC | % | -20 | |
relative positive tolerance of the control supply voltage at DC | % | 20 | |
display version for fault signal | red | ||
Mechanical data | |||
size of engine control device | S0 | ||
width | mm | 45 | |
height | mm | 125 | |
depth | mm | 155 | |
fastening method | screw and snap-on mounting | ||
mounting position | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t |
||
required spacing with side-by-side mounting | |||
upwards | mm | 60 | |
at the side | mm | 15 | |
downwards | mm | 40 | |
wire length maximum | m | 300 | |
number of poles for main current circuit | 3 | ||
Connections/ Terminals | |||
type of electrical connection | |||
for main current circuit | screw-type terminals | ||
for auxiliary and control circuit | screw-type terminals | ||
number of NC contacts for auxiliary contacts | 0 | ||
number of NO contacts for auxiliary contacts | 2 | ||
number of CO contacts for auxiliary contacts | 1 | ||
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point | |||
solid | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² | ||
finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) | ||
type of connectable conductor cross-sections for AWG cables for main contacts for box terminal | |||
using the front clamping point | 1x 8, 2x (16 ... 10) | ||
type of connectable conductor cross-sections for auxiliary contacts | |||
solid | 2x (0.5 ... 2.5 mm²) | ||
finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) | ||
type of connectable conductor cross-sections for AWG cables |